Data Center Applications

NovaTorque's innovative permanent magnet motor design delivers a 30% to 50% reduction in motor energy losses (wasted energy) when compared to today's NEMA Premium® efficiency induction motors. In typical variable speed applications those reductions in energy losses result in a 5% to 20% reduction in energy usage. Over the life of the motor, that's huge!

From its inception, NovaTorque's mission has been to reduce unnecessary consumption of energy by providing products that, without sacrificing performance, are at once more energy efficient and more cost effective than the products they are designed to replace.

A Closer Look at Motors in Data Centers
Efficient fan and motor selections are essential to achieving low PUE

Current Situation

Many of today's air handlers for data centers are designed for high flow rates and relatively low static pressures. The fans selected are consequently large and operate at relatively low speeds, typically 400 to 700 RPM. The problem for equipment designers, with preference to direct drive designs, is to select a motor with sufficient torque for the application, yet sufficiently energy efficient at these low rpms.

Challenge

To compound the problem, nearly all HVAC fans in data centers are driven by VFDs, where both the motor and drive efficiencies affect power consumption. In variable torque applications, such as fans, the motor and drive efficiency is a function of speed. A motor operating at less than nameplate speed suffers reduced efficiency. At approximately 50% of rated speed and below, induction motor efficiency begins to fall precipitously, significantly impacting the system efficiency and cooling costs. In the region of 400 to 700 RPM, where many HVAC cooling fans would run in an ideal design, the
combined efficiency of a premium induction motor and drive system is on the order of 75% or less!

Solution

NovaTorque motors not only achieve full speed efficiency several points above induction motors, but are able to maintain that high efficiency over a much wider speed range making them the perfect solution for data center cooling applications. Additionally NovaTorque's motors are uniquely able to handle the full load requirements of the fan as speeds near zero so there is no loss in fan performance at the lower speeds.

Results

On a recent project comparing a leading national brand's Premium efficiency induction motor to a NovaTorque PremiumPlus+ motor, a power reduction of 18% was achieved at identical operating conditions on the same VFD and air handler. This becomes quite significant on a data center project with multiple identical units operating 24 hours a day.

Improvements in energy efficiency lead to large reductions in energy bills and carbon emissions.

 

Benefits of NovaTorque Motors for Data Center Owners & HVAC Equipment OEMs

For Expanding and New Data Centers:

  • Easy, cost effective means to improve cooling system efficiency, hence directly impact data center PUE
  • 5% to 20% reduction in motor energy use, the primary energy consumer in data center cooling systems, year after year
  • Easily integrated into existing design specifications due to NEMA dimensions, VFD compatibility, UL listing, conformance with EC motor definition
  • Cost effective method of meeting current and future higher systems-based regulatory efficiency standards
  • Ideal for all variable speed applications, but with pronounced advantages in direct drive low speed applications
  • Allows for elimination of belt drives and the maintenance required, dust produced, and inefficiencies injected into the system

For Data Center HVAC Providers:

  • Easy, cost effective means to improve cooling system efficiency, hence directly impact data center PUE
  • Cost effective method of meeting current and future higher systems-based regulatory efficiency standards
  • Meets definition of electronically commutated (ECM) motors
  • Ideal for all variable speed applications, with pronounced advantages in direct drive low speed applications
  • Conforms to standard NEMA dimensions, so no special modifications or adjustments are required
  • UL listed
  • Compatible with all leading VFD brands

For Retrofitting of Existing Data Centers:

  • 30% to 50% reduction in motor losses (wasted energy)
  • A 5% to 20% reduction in energy consumed — compared to NEMA Premium induction motors
  • Easy motor substitution due to conformance with standard NEMA dimensions
  • Potential to remove belt driven fans to reduce air contamination, maintenance costs, and improve reliability
  • Compatibility with all leading VFD brands
  • Utility rebate/incentive qualified (utility program dependent)
  • Easy method of improving data center PUE
  • New differentiator for attracting clients with efficiency and sustainability objectives